[1] |
Beeres M,Schell B,Mastragelopoulos A,et al.High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation:initial experience[J]. Eur Radiol,2012,22(1):129-137.
|
[2] |
Karlo C,Leschka S,Goetti RP,et al.High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization[J]. Eur Radiol,2011,21(1):205-212.
|
[3] |
Achenbach S,Goroll T,Seltmann M,et al.Detection of coronary artery stenoses by low-dose,prospectively ECG-triggered,high-pitch spiral coronary CT angiography[J]. JACC Cardiovasc Imaging,2011,4(4):328-337.
|
[4] |
Hell MM,Bittner D,Schuhbaeck A,et al.Prospectively ECG-triggered high-pitch coronaryangiography with third-generation dual-source CT at 70 kVp tube voltage:Feasibility,image quality,radiation dose,and effect of iterative reconstruction[J]. J Cardiovasc Comput Tomogr,2014,8(6):418-425.
|
[5] |
Sommer WH,Schenzle JC,Becker CR,et al.Saving dose in triple-rule-out computed tomography examination using a high-pitch dual spiral technique[J]. Invest Radiol,2010,45(2):64-71.
|
[6] |
Kerl JM,Lehnert T,Schell B,et al.Intravenous contrast material administration at high-pitch dual-source CT pulmonary angiography:test bolus versus bolus-tracking technique[J]. Eur J Radiol,2012,81(10):2887-2891.
|
[7] |
Shin HJ,Kim SS,Lee JH,et al.Feasibility of low-concentration iodinated contrast medium with lower-tube-voltage dual-source CT aortography using iterative reconstruction:comparison with automatic exposure control CT aortography[J]. Int J Cardiovasc Imaging,2016,32(1):53-61.
|
[8] |
Zhang LJ,Li X,Schoepf UJ,et al.Non-electrocardiogram-triggered 70-kVp high-pitch computed tomography angiography of the whole aorta with iterative reconstruction:initial results[J]. J Comput Assist Tomogr,2016,40(1):109-117.
|
[9] |
Shen Y,Sun Z,Xu L,et al.High-pitch,low-voltage and low-iodine-concentration CT angiography of aorta:assessment of image quality and radiation dose with iterative reconstruction[J]. PLoS One,2015,10(2):e0117469.
|
[10] |
Raman SP,Mahesh M,Blasko RV,et al.CT scan parameters and radiationdose:practical advice for radiologists[J]. J Am Coll Radiol,2013,10(11):840-846.
|
[11] |
Winklehner A,Goetti R,Baumueller S,et al.Automated attenuation-based tube potential selection for thoracoabdominal computed tomography angiography:improved dose effectiveness[J]. Invest Radiol,2011,46(12):767-773.
|
[12] |
Frellesen C,Stock W,Kerl JM,et al.Topogram-based automated selection of the tube potential and current in thoraco-abdominal trauma CT-a comparison to fixed kV with mAs modulation alone[J]. Eur Radiol,2014,24(7):1725-1734.
|
[13] |
Beeres M,Romer M,Bodelle B,et al.Chest-abdomen-pelvis CT for staging in cancer patients:dose effectiveness and image quality using automated attenuation-based tube potential selection[J]. Cancer Imaging,2014,14(1):28-35.
|
[14] |
McCollough C,Edyvean S,Cody D,et al. AAPM report no. 96:the measurement,reporting,and management of radiation dose in CT—report of AAPM Task Group 23 of the Diagnostic Imaging Council CT Committee[C]. College Park,MD:American Association of Physicists,2008:11-13.
|
[15] |
Beeres M,Williams K,Bauer RW,et al.First clinical evaluation of high-pitch dual-source computed tomographic angiography comparing automated tube potential selection with automated tube current modulation[J]. J Comput Assist Tomogr,2015,39(4):624-628.
|